Introduction | Language Structure | IB Statements | File System | Comet 32 Runtime | Index |
Syntax: | DSTAT(device-name [,EXCP=statement-label]) |
Discussion: |
The DSTAT function returns the current status of system devices.
The device-name is the name of the device to be checked. The device-name may be a string constant, a single-element string variable, a string array element, a string expression, or a string function. |
Detailed information: |
DSTAT of the console DSTAT of remote terminals DSTAT of a local printer DSTAT of a remote printer DSTAT of a spooler DSTAT of the system driver (X00) DSTAT of a gateway DSTAT of a directory DSTAT of the clock |
DSTAT of the console:
Position Length Description/Values
============================================================
1 3 Partition
4 1 Type
0 = Monochrome
1 = Color
2 = Monochrome with flicker-free adapter
3 = Color with flicker-free adapter
4 = EGA/VGA/MCGA Monochrome
5 = EGA/VGA/MCGA Color
6 = TeleVideo
7 = AT&T
5 1 Option
01H = Force 80-column mode
02H = Force CR the same as Qantel
04H = Auto increment cursor
08H = FAST option enabled for all files
10H = Insert key is the same as Qantel
20H = Use expanded memory for all partitions
40H = Standard I/O for keyboard
6 1 Status
7 1 Foreground attribute (color)
8 1 Background attribute (color)
9 1 Invisible attribute (color)
10 1 Border attribute (color)
11 1 Entry attribute (color)
12 2 Base address
14 2 Current column and row
16 1 BIOS mode for 132-column
17 1 Current number of columns on screen
21 1 Returns "@01@" if the session is CometAnywhere
DSTAT of remote terminals:
Position Length Description/Values
===================================================================
1 3 Partition
4 1 Type
80H = dumb terminal
81H = TeleVideo terminal
82H = Ampex terminal
83H = Qantel VT3 terminal
84H = Qantel VT6 terminal
86H = QTerm workstation
F0H = Intermec bar code reader
FEH = RDI printer
FFH = ignored terminal
5 1 not used
6 1 Status
7 1 UART
8 1 Poll address
9 1 Terminal flag
80H OBP Terminal Lockout (Signal to PC that FG
processing loop is active on this terminal
and effectively locks out PC from changing
anything in the term table.)
20H Status Poll Hold Request (PC signals don't
do status poll on this terminal.)
10H Select Request (OBP should initiate a
select poll (data is in the buffer)
08H Buffer In Use Flag (OBP should not
initiate a data poll)
04H Data Poll Ack Request (PC has received the
data and the buffer is clear)
02H Reset Request (user has hit Escape)
01H Data Poll Request
10 1 Terminal process
Foreground Attention Needed
0 = IDLE - Dead terminal
1 = IDLE - Active terminal
2 = Status Poll Complete
8 = Waiting to send buffer to PC
9 = Finished select - OK
A = Finished select - NG
B = Data poll complete (ACK included)
UART is Working on this one
10H = Doing status poll
11H = Receiving data from terminal
12H = Sending data to terminal
13H = Retransmitting to terminal (1st
retransmit)
14H = Retransmitting to terminal (2nd
retransmit)
15H = Terminal reset in progress
DSTAT of a local printer (effective with build 319):
Position Length Description
=========================================
1 3 owning partition, if any
4 1 printer type in hex: 0=Local; 4=Windows
5 1 spool type in hex
To convert the type, take the HEXASC of the byte.
Look at the first character returned by HEXASC:
'6'=Auto-spool; 'A'=Exception spool; '2'=Non-spool
6 12 spooler alias name
18 237 pathname associated with the printer
DSTAT of a remote printer:
Position Length Description
=========================================
1 3 Partition
4 1 Type
5 1 Spool Type
6 1 Status
7 1 UART
8 1 Poll Address
9 1 Terminal Flag
10 1 Terminal Process
11 1 ROM Version
DSTAT of a spooler:
Position Length Description
=====================================
1 64 DOS path name
DSTAT of the system driver (X00):
Position Length Description
===================================================
1 32 (reserved)
33 16 Network node name
49 2 Number of the of first partiton
on the node (byte-reversed hex)
51 2 Total number of partitions on
the node (byte-reversed hex)
53 1 "@01@" if the user has a COM license; "@00@" otherwise
DSTAT of a gateway:
Position Length Description
=============================================
1 3 Controlling partition
4 1 Gateway type (hex)
5 1 Gateway subtype (hex)
DSTAT of a directory:
Position Length Description
======================================
1 3 Directory name
4 64 DOS path name
DSTAT of the clock:
Position Length Description
===================================
1 3 Clock name